Details:
The instrument is based on national industry standards JTJ052 "highway construction asphalt and asphalt test code" in the T0623 "Asphalt Saybolt viscosity test (Saybolt Heavy Oil Viscometer Method)" the requirements of the design and manufacture of suitable for high temperature measurement of viscous oil on asphalt, liquid asphalt and other conditions of oil viscosity, and is used to determine the temperature of asphalt construction.
Main Technical Data:
1 ©p Power Supply: AC 220V ± 10% 50Hz;
2, Type: Desktop;
3, working mode: Dual testing, parallel testing;
4, sample accept the bottle specification: 60 ± 0.05ml;
5 ©p bath heating power: 1000W;
6 ©p bath temperature: room temperature ~ 240.0 °C;
7 ©p bath temperature control accuracy: ± 0.1 °C;
8, test time range: 0.0s ~ 999.9s; 9, test timing accuracy: ± 0.1s;